If you’ve ever been in close proximity to a cryogenic cylinder when the safety relief valve pops open, you know it’s jarringly loud, almost like a shotgun blast. From a safety standpoint, the noise is high enough in decibels (over 100dB) to cause hearing damage if a worker is close enough to the valve. And from a plain nuisance perspective, it’s extremely startling and disruptive.
To eliminate the safety hazard and the nuisance factor, Generant re-designed the LCV series as a back pressure regulator that works a little differently. As the pressure comes up in the cylinder, the LCV valve begins to chatter and relieve product in a more natural state, lowering the decibel level by approximately 30 or 40 to a much more tolerable and safer amount that complies with OSHA sound level regulations.
The LCV also incorporates Generant’s “dirt guard” poppet, which prevents contaminants and debris and greatly reduces the likelihood of valve failure. No other valve in the industry has this feature.
Key Features:
Technical Data: